Test Equipment

MEDTEQ is continuing to develop a moderate range of equipment associated with medical particular
standards (IEC 60601-2-xx) for use in patient monitoring (ECG, NIBP, IBP), precision temperature (infant
incubators, warmers) and high frequency surgical applications (ESU, endoscopes).

 A full list of equipment, standards, links to instruction manuals and ordering given below.

As of January 1, 2014,  sales of ECG related equipment (SECG, MECG, CMRR, ECG set) are being handled by
Whaleteq in Taiwan. Please contact Mr. Nathan Lin for pricing and delivery schedule (nathan.lin@whaleteq.com)

For all other equipment, please contact Peter Selvey (peter.selvey@medteq.jp)

Model

Equipment

Standards

Links / Downloads

HFIT 7.0

High Frequency Insulation Tester, available for peak voltages up to 7200Vp / 100pF load

IEC 60601-2-2

IEC 60601-2-18

Overview

Operation Manual

Introductory Video 

Brochure

SECG 4.0 Performance testing equipment for ECG standards

IEC 60601-2-25
IEC 60601-2-27
IEC 60601-2-47
AAMI EC 11, EC 13

WhaleTeq SECG

MECG 2.0 Database testing for ECG standards (CTS, CSE, AHA, MIT etc.)

IEC 60601-2-25
IEC 60601-2-47
AAMI EC 57

WhaleTeq MECG
CMRR 2.0 Common Mode Rejection Ratio Test (CMRR) for ECG standards

IEC 60601-2-25
IEC 60601-2-27
IEC 60601-2-47
AAMI EC 11, EC 13

WhaleTeq CMRR

IBPS 1.0

 

IBP Simulator

For testing patient monitors with simulated static, sine and biological waveforms using 5µV/V/mmHg

(USB Module)

IEC 60601-2-34

Overview

Operation Manual

Software

USB driver

PPS 3.0

Precision pressure sensor

High accuracy, high speed system with graphical display intended for NIBP (400mmHg range model) or infusion pumps (220kPa model)
(USB module)

IEC 60601-2-24

IEC 60601-2-30

Overview

Operation Manual

Software

USB driver

HBTS 1.0

Human Body Thermometry System

Accurate measurement of temperature in the human body range (10-50°C, resolution 0.01°C) 
(8 channel, USB module)

IEC 60601-1
IEC 60601-2-18
IEC 60601-2-19
IEC 60601-2-20
IEC 60601-2-21
ISO 9919 etc

Overview

Operation Manual

Software

USB driver

SRJ

IBP Sensor Step Response Jig

Interfaces between sensor and oscilloscope, output 1V/100mmHg, used to verify frequency response of IBP sensors (5uV/V/mmHg)

IEC 60601-2-34

Contact MEDTEQ

 

HFCN

High Frequency Coupling Network

Network as indicated in the standard (500ohm, HF power resisors, 51k/47n network) for testing immunity from electrosurgury interference

IEC 60601-2-25
IEC 60601-2-27
IEC 60601-2-49

Contact MEDTEQ
HFPA100 

High Frequency Power Amplifier 

Intended for neutral electrode impedance test (200k - 5MHz, 200mA, up to 50ohm)

IEC 60601-2-2 WhaleTeq HFPA100